Part Number Hot Search : 
TLHR4405 150N20P V5X11 SL5511 BMS4003 2SC29 2220A AZ10EL32
Product Description
Full Text Search
 

To Download JA1A-TM-DC12 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 1 HORSE-POWER COMPACT POWER RELAYS
JA-RELAYS
30.1 1.185
34.7 1.366
30.1 1.185
34.7 1.366
FEATURES
28.5 1.122
28.5 1.122
TMP type
TM type
mm inch
* High switching capacity -- 55 A inrush, 15 A steady state inductive load (1 Form A) * Particularly suitable for air conditioners, dish washers, microwave ovens, ranges, central cleaning systems, copiers, facsimiles, etc. * Two types available "TM" type for direct chassis mounting "TMP" type for PC board mounting * TV-rated types available * TUV also approved
SPECIFICATIONS
Contact
Arrangement Initial contact resistance, max. (By voltage drop 6 V DC 1 A) Contact material Maximum switching power Rating (resistive Maximum switching voltage load) Max. switching current Mechanical (at 180 cpm.) 1 Form A (Inrush 55 A, Expected Steady 15 A 250 VAC life (min. cos = 0.7) Electrical operations) (at 20 cpm.) 1 Form B, 1 Form C (15 A 250 VAC, cos = 1)
1 Form, A, 1 Form B, 1 Form C
Characteristics
30 m Silver alloy 3,750 VA 250 V AC 15A 5x106 105
Maximum operating speed Initial insulation resistance*1 Between open contacts Initial breakdown voltage*2 Between contacts and coil
Initial surge voltage between contacts and coil*3 Operate time*4 (at 20C) (at nominal voltage) Release time (without diode)*4 (at 20C) (at nominal voltage) Temperature rise (at 50C) (resistive) Shock resis- Functional*6 tance Destructive*7 Vibration resistance Functional*8 Destructive
Coil
Nominal operating power Minimum operating power Remarks DC type AC type DC type AC type
* Specifications will vary with foreign standards certification ratings. *1 Measurement at same location as "Initial breakdown voltage" section *2 Detection current: 10mA *3 Wave is standard shock voltage of 1.2 x 50s according to JEC-212-1981 *4 Excluding contact bounce time *5 For the AC coil types, the operate/release time will differ depending on the phase.
*6Half-wave pulse of sine wave: 11ms; detection time: 10s
TYPICAL APPLICATIONS
Air conditioners, microwave ovens, load management equipment, copiers, process control equipment
w
w
w
1.4 VA (50 Hz)/1.3 VA (60 Hz) 0.77 W 0.90 VA (50 Hz)/0.84 VA (60 Hz)
t a .D
5x105 1.2 W Ex. JA
S a
e h
U t4 e
.c
m o
20 cpm. Min. 100 M at 500 V DC 1,500 Vrms 2,000 Vrms Min. 5,000 V Approx. 10 ms*5 Approx. 2 ms*5 Max. 70C
98 m/s2 {10 G} 980 m/s2 {100 G} 88.2 m/s2 {9 G}, 10 to 55 Hz at double amplitude of 1.5 mm 88.2 m/s2 {9 G}, 10 to 55 Hz at double amplitude of 1.5 mm -10C to +50C +14F to +122F 5 to 85%R.H. Approx. 44 g 1.55 oz
Ambient Conditions for operation, transport and storage*9 temp. (Not freezing and condensHumidity ing at low temperature) Unit weight
*7 Half-wave pulse of sine wave: 6ms *8 Detection time: 10s *9 Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 24).
ORDERING INFORMATION
1a TM DC12V P
Contact arrangement 1c: 1 Form C 1a: 1 Form A 1b: 1 Form B
Mounting classification
Coil voltage
TM: Solder Terminal TMP: Solder Teminal and PCB Teminal
DC 12, 24 V AC 12, 24, 115 V
(Notes) 1. For UL/CSA recognized types, add suffix UL/CSA. (Notes) 2. Standard packing Carton: 20 pcs.; Case: 200 pcs.
110
w
w
w
.D
at
aS
Nil: Standard type P: Up-graded contact rating type (See next page)
ee h
4U t
om .c
Classification
JA
COIL DATA
DC Type at 20C 68F
Nominal voltage 12 V DC 24 Pick-up voltage (max.) 9.6 V DC 19.2 Drop-out* voltage (min.) 1.2 (0.6*) V DC 2.4 (1.2*) Coil resistance, W (10%) 120 480 Nominal operating current, mA (10%) 100 50 Nominal operating power 1.2 W 1.2 Maximum allowable voltage (at 50C) 13.2 V DC 26.4
AC Type at 20C 68F
Nominal voltage 12 V AC Pick-up voltage (max.) 9.6 V AC Drop-out* voltage (min.) 3.6 V AC Coil resistance, W (10%) -- -- -- Nominal operating current, mA (10%) 50 Hz 60 Hz 117 108 58 54 12 11 Nominal operating power 50 Hz 60 Hz 1.4 VA 1.3 VA 1.4 VA 1.3 VA 1.4 VA 1.3 VA Maximum allowable voltage (at 50C) 13.2 V DC 26.4 126.5
24 19.2 7.2 115 92 34.5 * Drop-out voltage for 1 Form B type is 5% of nominal voltage.
NOTES 1. The range of coil current for AC relay is 15% (60 Hz). For DC relay it is 10% at 20C 68F. 2. The JA relay will operate in a range from 80% to 110% of the nominal coil voltage. It is however, recommended that the relay be used in the range of 85% to 110% of the nominal coil voltage, with the temporary voltage variation taken into consideration.
3. When the operating voltage of AC relays drops below 80% of the nominal coil voltage. The relay will generate a considerable amount of heat which is not recommended for maximum efficiency.
4. The coil resistance of DC types is the measured value of the coil at a temperature of 20C (68F). If the coil temperature changes by 1C. The measured value of the coil resistance should be increased or decreased by 0.4%.
ADDITIONAL SERIES
1. Following up-graded contact rating types recognized by UL are available. (For use in office appliances)
Suffix Contact arrangement 1 Form C 1 Form A 1 Form B P (Ex. JA 1a - TM - DC12V -P) Contact arrangement 1 Form A
2. TV-Rated Series
Suffix UL TV TV-5 CSA TV TV-5
25 A 250 V AC, 1 HP 125, 250 V AC 25 A 250 V AC, 1 HP 125, 250 V AC 25 A 250 V AC, 1 HP 125, 250 V AC mm inch
DIMENSIONS
TM
4.5 .177
Schematic (Bottom view)
COM
1 Form A
COM
N.O. 50 1.969 43.5 1.713
COM
1 Form B
R 2. 2
N.C.
5
30.1 1.185
34.7 1.366 2 .079 37.8 6.5 .256 1.488 9.3 .366
COM
1 Form C
N.C. N.O.
12.7 .500
FASTON 250
21.5 .846
FASTON 187
Terminals--.187" quick connect terminals for coil and .250" for contacts
Mounting hole location
COM
43.50.1 1.713.004
NC
NO
Remarks Above dimensions are for 1 Form C type. For 1 Form A type, NC terminal is removed For 1 Form B type, NO terminal is removed.
General tolerance: 0.3 .012
2-4.50.1 DIA. 2-.177.004 DIA.
Tolerance: 0.1 .004
111
JA
TMP
0.50.1 .020.004 4.5 .177 0.50.1 .020.004
mm inch
Schematic 1 Form A
Bottom view COM
Top view COM
50 1.969 43.5 1.713
COM
N.O. Bottom view COM Top view COM
25
25.4 1.000 30.1 1.185
0.80.1 .031.004
34.7 1.366 14 .551 1.5 .059
2.
1 Form B
3.5 .138 N.C. 2 .079 37.8 1.488 9.3 .366 Bottom view COM Top view COM
R
1 Form C
N.O. N.C.
12.7 .500
FASTON 250
21.5 .846
Terminals--PC board terminals for coils and .250" quick connect terminals forcontacts
COM
Mounting hole location
NC NO
General tolerance: 0.3 .012
2-4.50.1 DIA. 2-.177.004 DIA.
3-20.1 DIA. 3-.079.004 DIA. 43.50.1 1.713.004 140.1 .551.004
Remarks Above dimensions are for 1 Form C type. For 1 Form A type, NC terminal is removed For 1 Form B type, NO terminal is removed.
25.40.1 1.000.004
Tolerance: 0.1 .004
REFERENCE DATA
1. Maximum value for switching capacity (Common for 1a, 2b, and 1c)
20 Contact current, A 10 Temperature rise, C 5 Life x104 DCresistive load 100 50 250 V AC resistive load 30 V DC resistive load 80 60 40 20 AC resistive load
2. Life curve (Common for 1a, 1b, and 1c)
3.-(1) Coil temperature rise (1a-AC type)
Point measured: Inside the coil Ambient temperature: 25C 77F
500
100 Contact current 15A 10A 0A
1 0.5
0
30 50 100 200 400 500 Contact voltage, V
0
2
4
6
8 10 12 14 16 18 20 22 Contact current, A
0
80
90
100
110
120
Coil applied voltage, %V
3.-(2) Coil temperature rise (1a-DC type)
Point measured: Inside the coil Ambient temperature: 25C 77F
100 Temperature rise, C
4.-(1) Operate time (1a-AC type)
4.-(2) Operate time (1a-DC type)
20 18 Operating time, ms Contact current 15A Operating time, ms
20 18 16 14 12 10 8 6 Min. 4 2 80 90 100 110 120 0 80 90 100 110 120 Coil applied voltage, %V Max. Min.
80 60 40 20
16 14 12 10 8 6 4 2 Max.
10A 0A
0
80
90
100
110
120
0
Coil applied voltage, %V
Coil applied voltage, %V
112
JA
5.-(1) Release time (1a-AC type)
20 18 Release time, ms 16 14 12 10 8 6 4 2 0 80 90 100 110 120 Min. 0 80 90 100 110 120 1 Max. Release time, ms 4 3 2 Max. Min.
5.-(2) Release time (1a-DC type)
5
Coil applied voltage, %V
Coil applied voltage, %V
6.-(1) Electrical life (15 A 250 V AC resistive)
1. Tested sample: JA1c-TMP-AC115V 2. Load: 15 A 250 V AC resistive load 3. Cycle rate: 20 cpm. 4. Circuit:
TEST RESULT:
1. Pick-up and drop-out voltage
80 70 60 Voltage, *% 50 40 30 20 10 0 10 30 4 No. of operations, x10 50 Drop-out voltage Pick-up voltage Max. Max. Min. Min.
2. Contact resistance
Contact resistance, m 30 Max. Mean value Min. 10 30 No. of operations, x104 50
N.C. contact 10 0 30
N.C. N.C. 250 V AC
15 A 15 A
Contact resistance, m
10 0 10
N.C. contact Mean value 50
30 No. of operations, x104
* This shows percent rate against nominal coil voltage.
3. No abnormality was observed in either insulation resistance or breakdown voltage. 2. Contact resistance
10
6.-(2) Electrical life (15 A 250 V AC Motor simulated load)
1. Tested sample: JA1A-TM-DC12V 2. Load: 250 V AC inductive load (cos = 0.7) 15 A steady and 55 A (0.3s*) inrush current 3. Cycle rate: 20 cpm. 4. Circuit:
TEST RESULT:
1. Pick-up and drop-out voltage
10 9 8 Voltage, % 7 6 5 4 3 Pick-up voltage Max. Mean value Min.
Contact resistance, m
N.O. contact
Max. Mean value Min.
5
N.O.
250 V AC
R L
R L
2 1 0
Drop-out voltage
Max. Mean value Min. 0 10 5 10
4
5 4 No. of operations, x10
No. of operations, x10
3. No abnormality was observed in either insulation resistance or breakdown voltage.
For Cautions for Use, see Relay Technical Information (Page 11 to 39).
113


▲Up To Search▲   

 
Price & Availability of JA1A-TM-DC12

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X